@ -166,10 +166,6 @@ class SPIMaster(Module):
|
||||
Notes:
|
||||
* M = 32 is the data width (width of the data register,
|
||||
maximum write bits, maximum read bits)
|
||||
* If there is a miso wire in pads, the input and output can be done
|
||||
with two signals (a.k.a. 4-wire SPI), else mosi must be used for
|
||||
both output and input (a.k.a. 3-wire SPI) and config.half_duplex
|
||||
must to be set when reading data is desired.
|
||||
* Every transfer consists of a write_length 0-M bit write followed
|
||||
by a read_length 0-M bit read.
|
||||
* cs_n is asserted at the beginning and deasserted at the end of the
|
||||
@ -184,29 +180,37 @@ class SPIMaster(Module):
|
||||
"cs_n all deasserted" means "all cs_n bits high".
|
||||
* cs is not mandatory in pads. Framing and chip selection can also
|
||||
be handled independently through other means.
|
||||
* If there is a miso wire in pads, the input and output can be done
|
||||
with two signals (a.k.a. 4-wire SPI), else mosi must be used for
|
||||
both output and input (a.k.a. 3-wire SPI) and config.half_duplex
|
||||
must to be set when reading data is desired.
|
||||
* For 4-wire SPI only the sum of read_length and write_length matters.
|
||||
The behavior is the same no matter how the total transfer length is
|
||||
divided between the two. For 3-wire SPI, the direction of mosi/miso
|
||||
is switched from output to input after write_len cycles, at the
|
||||
"shift_out" clk edge corresponding to bit write_length + 1 of the
|
||||
transfer.
|
||||
* The first bit output on mosi is always the MSB/LSB (depending on
|
||||
config.lsb_first) of the data register, independent of
|
||||
xfer.write_len. The last bit input from miso always ends up in
|
||||
the LSB/MSB (respectively) of the data register, independent of
|
||||
read_len.
|
||||
* For 4-wire SPI only the sum of read_len and write_len matters. The
|
||||
behavior is the same no matter how the total transfer length is
|
||||
divided between the two. For 3-wire SPI, the direction of mosi/miso
|
||||
is switched from output to input after write_len cycles, at the
|
||||
"shift_out" clk edge corresponding to bit write_length + 1 of the
|
||||
transfer.
|
||||
* Data output on mosi in 4-wire SPI during the read cycles is what
|
||||
is found in the data register at the time.
|
||||
Data in the data register outside the least/most (depending
|
||||
on config.lsb_first) significant read_length bits is what is
|
||||
seen on miso during the write cycles.
|
||||
* The SPI data register is double-buffered: once a transfer completes,
|
||||
the previous transfer's read data is available in the data register
|
||||
and new write data can be written, queuing a new transfer. Transfers
|
||||
submitted this way are chained and executed without deasserting cs.
|
||||
* The SPI data register is double-buffered: Once a transfer has
|
||||
started, new write data can be written, queuing a new transfer.
|
||||
Transfers submitted this way are chained and executed without
|
||||
deasserting cs. Once a transfer completes, the previous transfer's
|
||||
read data is available in the data register.
|
||||
* A wishbone transaction is ack-ed when the transfer has been written
|
||||
to the intermediate buffer. It will be started when there are no
|
||||
other transactions being executed.
|
||||
other transactions being executed. Writes take one cycle when
|
||||
there is either no transfer being executed, no data in the
|
||||
intermediate buffer, or a transfer just completing. Reads always
|
||||
finish in one cycle.
|
||||
|
||||
Transaction Sequence:
|
||||
* If desired, write the config register to set up the core.
|
||||
@ -215,28 +219,30 @@ class SPIMaster(Module):
|
||||
writing triggers the transfer and when the transfer is accepted to
|
||||
the inermediate buffer, the write is ack-ed.
|
||||
* If desired, read the data register.
|
||||
* If desired write xfer and data for the next, chained, transfer
|
||||
* If desired, write data for the next, chained, transfer.
|
||||
|
||||
Register address and bit map:
|
||||
|
||||
config (address 2):
|
||||
1 offline: all pins high-z (reset=1)
|
||||
1 active: cs/transfer active
|
||||
1 active: cs/transfer active (read-only)
|
||||
1 pending: transfer pending in intermediate buffer, bus writes will
|
||||
block
|
||||
block (read-only)
|
||||
1 cs_polarity: active level of chip select (reset=0)
|
||||
1 clk_polarity: idle level for clk (reset=0)
|
||||
1 clk_polarity: idle level of clk (reset=0)
|
||||
1 clk_phase: first edge after cs assertion to sample data on (reset=0)
|
||||
(clk_polarity, clk_phase) == (CPOL, CPHA) in Freescale language.
|
||||
(0, 0): idle low, output on falling, input on rising
|
||||
(0, 1): idle low, output on rising, input on falling
|
||||
(1, 0): idle high, output on rising, input on falling
|
||||
(1, 1): idle high, output on falling, input on rising
|
||||
There is never a clk edge during a cs edge.
|
||||
1 lsb_first: LSB is the first bit on the wire (reset=0)
|
||||
1 half_duplex: 3-wire SPI, in/out on mosi (reset=0)
|
||||
8 undefined
|
||||
8 div_write: counter load value to divide this module's clock
|
||||
to the SPI write clk.
|
||||
f_clk/f_spi_write == 2*(div_write + 1) (reset=0)
|
||||
to generate the SPI write clk (reset=0)
|
||||
f_clk/f_spi_write == div_write + 2
|
||||
8 div_read: ditto for the read clock
|
||||
|
||||
xfer (address 1):
|
||||
@ -338,12 +344,14 @@ class SPIMaster(Module):
|
||||
|
||||
clk_t = TSTriple()
|
||||
self.specials += clk_t.get_tristate(pads.clk)
|
||||
mosi_t = TSTriple()
|
||||
self.specials += mosi_t.get_tristate(pads.mosi)
|
||||
|
||||
self.comb += [
|
||||
clk_t.oe.eq(~config.offline),
|
||||
clk_t.o.eq((spi.cg.clk & spi.cs) ^ config.clk_polarity),
|
||||
]
|
||||
|
||||
mosi_t = TSTriple()
|
||||
self.specials += mosi_t.get_tristate(pads.mosi)
|
||||
self.comb += [
|
||||
mosi_t.oe.eq(~config.offline & spi.cs &
|
||||
(spi.oe | ~config.half_duplex)),
|
||||
mosi_t.o.eq(spi.reg.o),
|
||||
|