spi2: fixes

This commit is contained in:
Robert Jördens 2018-02-21 18:26:51 +00:00 committed by Robert Jordens
parent 5eda894db4
commit 898bad5abc
1 changed files with 3 additions and 7 deletions

View File

@ -7,9 +7,7 @@ Output event replacement is not supported and issuing commands at the same
time is an error.
"""
from numpy import int64
from artiq.language.core import syscall, kernel, portable, now_mu, delay_mu
from artiq.language.types import TInt32, TNone
from artiq.coredevice.rtio import rtio_output, rtio_input_data
@ -72,11 +70,10 @@ class SPIMaster:
@portable
def frequency_to_div(self, f):
"""Convert a SPI clock frequency to the closest SPI clock divider."""
return int64(round(
1/(f*self.core.mu_to_seconds(self.ref_period_mu))))
return int(round(1/(f*self.core.mu_to_seconds(self.ref_period_mu))))
@kernel
def set_config(self, flags, length, freq, c):
def set_config(self, flags, length, freq, cs):
"""Set the configuration register.
* If ``SPI_CS_POLARITY`` is cleared (``cs`` active low, the default),
@ -140,8 +137,7 @@ class SPIMaster:
Or number of the chip select to assert if ``cs`` is decoded
downstream. (reset=0)
"""
self.set_config_mu(
flags, length, self.frequency_to_div(write_freq), cs)
self.set_config_mu(flags, length, self.frequency_to_div(freq), cs)
@kernel
def set_config_mu(self, flags, length, div, cs):