mirror of https://github.com/m-labs/artiq.git
work around firmware bug in KA3005P that impacts get_i()
This commit is contained in:
parent
010ce019b3
commit
2dd72fb94c
|
@ -38,10 +38,14 @@ class KoradKA3005P:
|
|||
async def _ser_read(self, fixed_length=None):
|
||||
""" strings returned by firmware are zero-terminated or fixed length
|
||||
"""
|
||||
r = ""
|
||||
if self.simulation:
|
||||
logger.info("simulation _ser_read()")
|
||||
else:
|
||||
c = (await self.port.read(1)).decode()
|
||||
r = c
|
||||
while len(c) > 0 and ord(c) != 0 and not len(r) == fixed_length:
|
||||
c = (await self.port.read(1)).decode()
|
||||
c = (await self.port.read(1)).decode().rstrip('\0')
|
||||
r += c
|
||||
logger.debug("_read %s: ", r)
|
||||
return r
|
||||
|
@ -106,21 +110,19 @@ class KoradKA3005P:
|
|||
|
||||
async def get_i(self):
|
||||
"""Request the current as set by the user. """
|
||||
|
||||
# ISET1? replies with a sixth byte on many models (all?)
|
||||
# which is the sixth character from *IDN?
|
||||
# reply if *IDN? was queried before (during same power cycle).
|
||||
# This byte is read and discarded.
|
||||
# Expected behavior of ISET1? is to return 5 bytes.
|
||||
# However, if *IDN? has been previously called, ISET1? replies
|
||||
# with a sixth byte 'K' which should be discarded. For consistency,
|
||||
# always call *IDN? before calling ISET1?.
|
||||
self.get_id()
|
||||
await self._ser_write("ISET1?")
|
||||
r = await self._ser_read(fixed_length=5)
|
||||
if r[0] == "K":
|
||||
r = r[1:-1]
|
||||
r = (await self._ser_read(fixed_length=6)).rstrip('K')
|
||||
return float(r)
|
||||
|
||||
async def measure_i(self):
|
||||
"""Request the actual output current."""
|
||||
await self._ser_write("IOUT1?")
|
||||
r = await self._ser_read(fixed_length=6)
|
||||
r = await self._ser_read(fixed_length=5)
|
||||
if r[0] == "K":
|
||||
r = r[1:-1]
|
||||
return float(r)
|
||||
|
|