rtio_clocking: inform the user if PLL is bypassed
This commit is contained in:
parent
ae3099dd8e
commit
ecd4ca333c
@ -264,7 +264,10 @@ pub fn init(timer: &mut GlobalTimer, cfg: &Config) {
|
||||
{
|
||||
let i2c = unsafe { (&mut i2c::I2C_BUS).as_mut().unwrap() };
|
||||
match clk {
|
||||
RtioClock::Ext0_Bypass => si5324::bypass(i2c, SI5324_EXT_INPUT, timer).expect("cannot bypass Si5324"),
|
||||
RtioClock::Ext0_Bypass => {
|
||||
info!("bypassing the PLL for RTIO clock");
|
||||
si5324::bypass(i2c, SI5324_EXT_INPUT, timer).expect("cannot bypass Si5324")
|
||||
}
|
||||
_ => setup_si5324(i2c, timer, clk),
|
||||
}
|
||||
}
|
||||
|
Loading…
Reference in New Issue
Block a user