rtio_clocking: inform the user if PLL is bypassed
This commit is contained in:
parent
ae3099dd8e
commit
ecd4ca333c
@ -264,7 +264,10 @@ pub fn init(timer: &mut GlobalTimer, cfg: &Config) {
|
|||||||
{
|
{
|
||||||
let i2c = unsafe { (&mut i2c::I2C_BUS).as_mut().unwrap() };
|
let i2c = unsafe { (&mut i2c::I2C_BUS).as_mut().unwrap() };
|
||||||
match clk {
|
match clk {
|
||||||
RtioClock::Ext0_Bypass => si5324::bypass(i2c, SI5324_EXT_INPUT, timer).expect("cannot bypass Si5324"),
|
RtioClock::Ext0_Bypass => {
|
||||||
|
info!("bypassing the PLL for RTIO clock");
|
||||||
|
si5324::bypass(i2c, SI5324_EXT_INPUT, timer).expect("cannot bypass Si5324")
|
||||||
|
}
|
||||||
_ => setup_si5324(i2c, timer, clk),
|
_ => setup_si5324(i2c, timer, clk),
|
||||||
}
|
}
|
||||||
}
|
}
|
||||||
|